ZS 71 Z

Features/Options

  • Metal enclosure
  • Wall mounting
  • Slow or snap action: 2 contacts
  • Pull-wire function with or without latching
    snap action: without latching
    slow action: with latching
  • Watertight collar W available for protection against penetration of dirt
  • Indicator lamps for various voltages are indicated in chapter accessories in the appendix

Product image

 

Technical data

Standards IEC/EN 60947-5-1
Enclosure aluminium die-cast, enamel finish
Cover thermoplastic, ultramid
Degree of protection IP 65 to IEC/EN 60529
Contact material silver
Switching elements change-over contact with double break with galvanically separated contact bridges
Switching system slow or snap action, positive break
NC contacts Zwangsöffnung to IEC 60947-5-1
Connection screw terminals
Cable section max. 2.5 mm2
(incl. conductor ferrules)
Cable entry 2 x M20 x 1.5
Uimp ZS 71 Z: 6 kV,
ZS 71 Z RE: 4 kV
Ui 400 V
Ithe ZS 71 Z: 6 A
ZS 71 Z RE: 4 A
Utilisation category AC-15
Ie/Ue ZS 71 Z: 6 A/400 VAC,
ZS 71 Z RE: 4 A/400 VAC
Max. fuse rating ZS 71 Z: 6 A gL/gG D-fuse
ZS 71 Z RE: 4 A gL/gG D-fuse
Ambient temperature –25 °C … +70 ºC
Mech. life > 1 million operations
Indicator lamp as option
Switching frequency 1800/h
Actuating force ZS 71 Z: max. 80 N,
ZS 71 Z RE: max. 80 N
Features pull-wire function with or without latching
Approvals BRD